CVE-2026-5078
Is CVE-2026-5078 real, exploitable, or a false positive? Here's the community verdict.
signals
public sources
Moderate signals. Triage by your actual exposure and reachability.
baseline read
auto · not a community verdict
Low signal — verdict needed
Few public signals point to active risk. Whether a scanner hit here is a true or false positive depends on your version and config — community verdicts decide.
Based on CVSS · FIRST EPSS
Confirm or dispute →CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Impact: The morgan logging middleware's :remote-user token extracts the Basic auth username from the Authorization request header and writes it to the log stream without neutralizing control characters. An unauthenticated attacker can send a crafted Authorization Basic header containing CR or LF bytes to inject forged log lines, breaking the one-request-per-line structure of access logs and enabling log forgery against downstream log consumers. The built-in combined, common, default, and short formats are affected, as well as any custom format that references :remote-user. Affected versions: morgan 1.2.0 through 1.10.1. Patches: upgrade to morgan 1.11.0, which neutralizes control characters in the :remote-user token output. Workarounds: use a custom format string that does not include :remote-user.
References
Published
Embed this verdict
[](https://www.truepositive.app/cve/CVE-2026-5078)<a href="https://www.truepositive.app/cve/CVE-2026-5078"><img src="https://www.truepositive.app/cve/CVE-2026-5078/badge.svg" alt="TruePositive verdict for CVE-2026-5078"></a>Live badge that updates automatically as the community verdict changes.
Community ground truth
Be the first practitioner to weigh in
So far this is only TruePositive's editorial baseline from public sources. Add your real-world verdict below — it becomes the signal the next person triaging this relies on.
🥇 The first 50 practitioners to contribute earn a Founding Contributor badge.
In your experience, is this finding real and exploitable?
awaiting field verdictsCurated baseline: A curated baseline from public sources, shown separately from community verdicts.
No account needed. Anonymous verdicts post as an unverified signal. Log in to make yours verified and earn reputation.
Field notes & remediation
Verdicts are the quick signal. Notes are the evidence and fixes behind them.
- 0
No confirmed in-the-wild exploitation or public exploit was found for this yet.
Add a field note or remediationoptional
Related CVEs
Same weakness: CWE-117.
- CVE-2026-9016MED 5.3EPSS 0%
The Debug Log Manager – Conveniently Monitor and Inspect Errors plugin for WordPress is vulnerable to Improper Output Neutralization for Logs in all versions up to, and including, 2.5.0. This is due to the `log_js_errors()` AJAX handler being registered for unauthenticated users via `wp_ajax_nopriv_log_js_errors` and gated only by a nonce that is publicly disclosed in every front-end page's HTML through `wp_localize_script()` whenever JavaScript error logging is enabled, providing no real authorization barrier. This makes it possible for unauthenticated attackers to inject arbitrary forged entries into the site's WordPress debug log by supplying attacker-controlled values for the `message`, `script`, `lineNo`, `columnNo`, and `pageUrl` fields — enabling spoofing of error and incident records, obscuring malicious activity within fabricated log noise, and misleading administrators who rely on the log for triage. This vulnerability is only exploitable when the plugin's JavaScript error logging feature is enabled, as the requisite nonce is only published into the page HTML under that condition.
- CVE-2026-45679MED 6.5EPSS 0%
OpenTelemetry eBPF Instrumentation provides eBPF instrumentation based on the OpenTelemetry standard. Prior to version 0.9.0, OBI exports raw Redis error text as the span status message. Because Redis error replies can contain attacker-controlled or sensitive values, this behavior can exfiltrate tokens, PII, or other confidential input into telemetry backends and inject untrusted text into downstream analysis systems. This issue has been patched in version 0.9.0.